Calibration
Although all Ergometers are calibrated at the fac-
tory the user may wish to verify this by perfor-
ming a mechanical scale calibration. If so please
do the following.
Remove the brake belt from the spring. Lean
the bike forward so that the calibration weight,
4kg(4) (our part no: 9000-211) is hanging inde-
pendently from the frame cover. Be sure that the
scale board is set to zero before the weight is put
on, see section ”Scale - zero adjustment”. Put the
weight on on the spring(6). When correctly set,
it should be possible to read this weight from the
corresponding place on the scale board(7). See
fig: Calibration.
Should there be a deviation, adjust the pendulum
to the correct weight on the scale by means of the
adjusting weight inside the pendelum(3). See fig:
Scale adjustment. To change the position of the
adjusting weight, loosen the lock screw(8) on the
back of the pendelum weight. Should the index
of the pendulum weight be too low, move the
adjusting weight upwards in the weight and if the
index should be too high the adjusting weight is
moved somewhat downwards and locked in the
new position. Repeat until the correct reading is
achieved.
Check the calibration of the pendulum weight
once a year or when needed.
Scale - zero adjustment
Loosen tension device so that the brake belt feels
loose. Check that the pendulum will hang in ver-
tical position.
Scale board:
Check that the index on the pendulum(2) weigh
is aligned with the index at the 0-position on
the scale board. If adjustment is necessary, first
loosen the lock nut(1) and then change the posi-
tion of the board. Tighten the lock nut after the
adjustment. See fig: Scale adjustments.
Kp-scale:
At the same time, check that the kilopond scale(5)
to the left of the meter, shows 0 in line with the
index. To adjust the kp-scale lossen the lock
screw for scale indicator(9). Tighten the screw
firmly after the adjustment. See fig: Calibration,
Adjustment kp-scale window.