Monark 828E Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
4
5
7
8
6
1
3
2
9
Monark 828 E
8
Calibration
Although all Ergometers are calibrated at the factory
the user may wish to verify this by performing a me-
chanical scale calibration. If so please do the follow-
ing.
Remove the brake belt from the spring. Lean the
bike forward so that the calibration weight, 4kg(4)
(Art. No: 9000-211) is hanging independently from
the frame cover. Be sure that the scale board is set to
zero before the weight is put on, see section ”Scale -
zero adjustment”. Put the weight on on the spring(6).
When correctly set, it should be possible to read this
weight from the corresponding place on the scale
board(7). See fig: Calibration.
Should there be a deviation, adjust the pendulum to
the correct weight on the scale by means of the ad-
justing weight inside the pendulum(3). See fig: Scale
adjustment. To change the position of the adjusting
weight, loosen the lock screw(8) on the back of the
pendulum weight. Should the index of the pendulum
weight be too low, move the adjusting weight upwards
in the weight and if the index should be too high the
adjusting weight is moved somewhat downwards and
locked in the new position. Repeat until the correct
reading is achieved.
Check the calibration of the pendulum weight once a
year or when needed.
Fig: Calibration
4) Calibration weight, 4kg
5) kp-scale
6) Attachment of calibration weight
7) Pendulum at 4kp
8) Screw to adjustment weight
Scale - zero adjustment
Loosen tension device so that the brake belt feels
loose. Check that the pendulum will hang in vertical
position.
Scale board:
Check that the index on the pendulum(2) weigh is
aligned with the index at the 0-position on the scale
board. If adjustment is necessary, first loosen the
locknut(1) and then change the position of the board.
Tighten the lock-nut after the adjustment. See fig:
Scale adjustments.
Kp-scale:
At the same time, check that the kilopond-scale(5) to
the left of the meter, shows 0 in line with the index.
To adjust the kp-scale loosen the lockscrew for scale
indicator(9). Tighten the screw firmly after the adjust-
ment. See fig: Calibration, Adjustment kp-scale win-
dow.
Fig: Scale adjustment
1) Locking nut
2) 0-index
3) Adjustment weight, pendulum
Fig: Adjustment kp-scale window
9) Lock screw for scale indicator
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments